Arc flash, protection grading and fault level studies for Australian sites
Vibhawa Consultants, electrical consultants in Sri Lanka, carries out ETAP arc flash hazard assessments to IEEE 1584-2018, protection grading and fault level studies for Australian HV and LV installations, working remotely from Colombo. Where a state requires a registered engineer, the study is reviewed and signed through registered Australian engineers. Send your single line diagram and we will return a fixed quote within 48 hours.
What you receive
- Incident energy and arc flash boundary at every switchboard
- PPE category for each location
- Arc flash labels ready to print
- Time-current (TCC) curves for each protection path
- Protection settings schedule for every relay and circuit breaker
- Fault level at each bus, with circuit breaker duty checks
- ETAP model handed over with the report
Studies we carry out
Each study is built in one ETAP model of your installation, so the arc flash, protection and fault level results agree with each other.
Review studies at least every five years, and after any change to fault level, protection settings or switchboards.
Standards we work to
| Standard | How we use it |
|---|---|
| IEEE 1584-2018 | Incident energy and arc flash boundary calculation |
| ENA NENS 09 | Used where the network operator or site owner specifies it instead of, or alongside, IEEE 1584 |
| AS/NZS 4836:2023, Appendix B | Arc flash assessment, labelling and approach boundaries |
| AS/NZS 3000 | Installation requirements behind protection and fault level checks |
| Energex/Ergon STNW3053 | Arc flash assessments for work on or connected to Energex and Ergon networks in Queensland |
| Network operator embedded generation requirements | Protection studies for connections from 30 kW to 1.5 MW, including the information an RPEQ compliance report needs in Queensland |
How a remote study works
We do the modelling and analysis in Colombo. You need to send data, not host a team on site. Our working day overlaps the Australian afternoon (AEST).
Send your SLD
A single line diagram is enough for us to quote.
Fixed quote in 48 h
Scope, price and programme, based on the number of buses and switchboards.
Data collection
We send a checklist: network fault level at the connection point, transformer, cable and protection device data, and current settings.
Study and report
ETAP model, report, labels and settings schedule. Signed through a registered Australian engineer where the state requires it.
Working with an Australian consultancy or switchboard builder? We also deliver studies under your brand, for your engineers to review and sign.
Australian work we have delivered
Snowy 2.0, NSW
For the 2,200 MW Snowy 2.0 pumped-hydro project, awarded to Vibhawa by Future Generation JV, we modelled and simulated the electricity distribution system of over 100 substations at 33 kV, 22 kV, 11 kV, 1,000 V and 415 V. The ETAP studies covered load flow, short circuit, protection coordination and arc flash. Read the Snowy 2.0 project or how we built the model.
EarthPower, NSW
HV system study and arc flash study of the motor control centres, delivered through an Australian engineering partner.
Veolia Woodlawn, NSW
HV and LV studies supporting the retrofit of the site's electrical installation, delivered through an Australian engineering partner.
Veolia AAD, Sydney (2023)
Power system study for a Veolia site in Sydney, delivered through an Australian engineering partner.
Compact modular substations for an Australian client
Two compact substations, 22 kV/1,000 V 1,200 kVA and 22 kV/400 V 1,000 kVA, and a 22 kV switch room with GIS switchgear, built to Australian standards. Vibhawa carried out the design, including arc flash studies, and the installation supervision, QA/QC and testing, together with the fabrication partner. Registered Australian engineers joined for certification.
Who signs the study
Studies are prepared in ETAP by Vibhawa's engineers under Nadeera Wijesinghe, a Chartered Electrical Engineer (IESL). Queensland (RPEQ), Victoria and the ACT require a registered professional engineer to carry out or directly supervise engineering services for projects in those states, even when the work is done overseas. For those projects, the study is reviewed and signed through registered Australian engineers. We agree the sign-off arrangement with you before the study starts.
Vibhawa is an ISO 9001:2015-certified company. See our certifications and affiliations →
What we don't do
We don't carry out DC arc flash studies. We don't carry out PSCAD or EMT modelling, so studies for NEM-registered generators above 5 MW that need AEMO generator performance standards are outside our scope. Testing on site in Australia is not part of this service.
Questions Australian clients ask
Is an arc flash study mandatory in Australia?
No single law names an arc flash study, but work health and safety law requires the risk from arc flash to be managed. Energy Safe Victoria's guideline expects owners of HV and complex LV installations to assess arc flash, using IEEE 1584 or a similar method, and AS/NZS 4836:2023 Appendix B covers assessment and labelling. In practice an arc flash hazard assessment is how most sites show they have managed the risk.
Should the study use IEEE 1584-2018 or ENA NENS 09?
IEEE 1584-2018 is the most widely used method and the one Energex and Ergon's STNW3053 specifies. Some network operators and site owners specify ENA NENS 09. We confirm the method with you, or with the network operator, before the study starts.
Can a study be done from overseas?
Yes. Arc flash, protection and fault level studies are desk studies built from your data. Our largest remote job is the Snowy 2.0 model of over 100 substations. For projects in Queensland, Victoria and the ACT, a registered Australian engineer must carry out or directly supervise the work, so we arrange sign-off through registered Australian engineers for those states.
What do you need to quote?
A single line diagram is enough for a fixed quote within 48 hours. Send it here. For the study itself we send a data checklist covering the network fault level at the connection point, transformers, cables, protection devices and their current settings.
How often should an arc flash study be updated?
Review it at least every five years, and sooner after any change to the network fault level, protection settings, transformers or switchboards.
Do you carry out embedded generation protection studies?
Yes. We carry out protection and fault level studies for solar PV and battery systems, including connections from 30 kW to 1.5 MW where the network operator asks for a study. Large generators above 5 MW that need AEMO modelling are outside our scope.
What does an arc flash study cost in Australia?
The price depends mainly on the number of buses and switchboards and how complete the data is. Send your single line diagram through our quote form and we will return a fixed price within 48 hours.
Can you work under our company's brand?
Yes. We prepare power system studies for Australian consultancies, EPCs and switchboard builders to review, sign and issue under their own name.
Explore related power system and electrical services
Arc Flash Study
Incident energy, PPE category and labels to IEEE 1584-2018, with mitigation options.
→ Explore Arc Flash StudyProtection Coordination Study
Relay and circuit breaker grading with TCC curves and a settings schedule.
→ Explore Protection CoordinationPower System Studies
Load flow, short circuit and other ETAP studies for HV and LV networks.
→ Explore Power System StudiesElectrical Consultancy
Design and design review of HV and LV installations, including modular substations.
→ Explore Electrical ConsultancyRelated locations
Electrical Testing & Consultancy in the Maldives
Testing, consultancy and design for resorts, including the offshore substation for the Cheval Blanc Randheli floating solar project.
→ Explore Our Maldives ServicesWhat clients say about Vibhawa
Vibhawa is rated by clients across Sri Lanka, the Maldives and internationally. See what they say about working with us.
Send your single line diagram
We'll return scope, price and programme within 48 hours. Prefer to talk first? Contact us.
Send your SLD